Technical Standards for Ceramic Tiles: ISO 13006, ISO 10545, EN 14411 and Slip

Technical Standards for Ceramic Tiles: ISO 13006, ISO 10545, EN 14411 and Slip

Tile data sheets are full of standard numbers: ISO 13006, EN 14411, ISO 10545-3, R10, PTV 36, DCOF 0.42. This page explains what each one means, which ones your market and your project actually need, and what to ask for before you order. One rule applies throughout: a value only counts if it comes from a test report for that product and finish. We publish values on our product pages only from reports we hold; everything else says “test report on request”.

Key takeaways

  • ISO 13006 (internationally) and EN 14411 (in Europe) classify tiles and set the minimum requirements; ISO 10545 is the set of test methods used to check them.
  • Porcelain and vitrified tiles are dry-pressed tiles with water absorption of 0.5% or less — group BIa.
  • For CE marking in the EU, the producing manufacturer issues a Declaration of Performance against the harmonised EN 14411.
  • Slip resistance has no pass mark in ISO 13006: ask for the method your market uses — R9–R13 ramp, pendulum (PTV), DCOF or AS 4586 classes.
  • Ask for the test report for the exact product, finish and thickness, with the laboratory, date and report number.

ISO 13006: how tiles are classified

ISO 13006:2018 defines ceramic tiles, classifies them and sets their characteristics and marking. It sorts tiles by two things: how they are formed — A for extruded, B for dry-pressed — and how much water the fired body absorbs (E).

GroupWater absorption (E)Common trade names
BIaE ≤ 0.5%Porcelain, vitrified, GVT / PGVT, full body, double charge, porcelain slabs
BIb0.5% < E ≤ 3%Semi-vitrified / stoneware
BIIa3% < E ≤ 6%Stoneware
BIIb6% < E ≤ 10%Semi-stoneware
BIIIE > 10%Ceramic wall tiles

For group BIa, the main requirements include an average water absorption of no more than 0.5% (no single tile above 0.6%), a breaking strength of at least 1,300 N for tiles 7.5 mm thick or more, and a modulus of rupture of at least 35 N/mm² on average. Length and width may vary by about ±0.6% of the work size and thickness by ±5%, and at least 95% of tiles must be free of visible surface defects. Each product page has a table of these requirements with the matching ISO 10545 method; the “product result” column fills in only from a report we hold.

EN 14411 and CE marking in Europe

EN 14411 is the European counterpart of ISO 13006, with the same groups. It matters most because it is the harmonised standard behind CE marking: tiles placed on the EU market need CE marking and a Declaration of Performance (DoP) drawn up by the producing manufacturer. The edition cited for CE marking is EN 14411:2012 — the later 2016 text has not been cited, so check that a DoP refers to the right edition. The EU’s new Construction Products Regulation (EU) 2024/3110 applies from 8 January 2026, but tiles keep the existing DoP route until a new harmonised specification is adopted. The UK uses the same standard for UKCA marking. See our EU market guide for duties and importer obligations.

ISO 10545: the test methods

ISO 10545 is a series of test methods, each published as a separate part. A test report should name the part used for every value.

PartWhat it testsWhen it matters
ISO 10545-2Dimensions and surface quality (size, thickness, straightness, flatness, defects)Every order; large formats and thin joints
ISO 10545-3Water absorptionConfirms the group (BIa for porcelain); frost and outdoor use
ISO 10545-4Modulus of rupture and breaking strengthFloors, commercial traffic, thin tiles
ISO 10545-6Deep abrasion of unglazed tilesFull body and unglazed floors
ISO 10545-7Surface abrasion of glazed tiles (PEI class 0–5)Glazed floors: the higher the class, the heavier the foot traffic
ISO 10545-8Linear thermal expansionUnderfloor heating, facades, sun-exposed areas
ISO 10545-9Thermal shock resistanceKitchens, outdoor areas
ISO 10545-10Moisture expansionMainly higher-absorption tiles
ISO 10545-11Crazing resistance of glazed tilesGlazed wall and floor tiles
ISO 10545-12Frost resistanceAny outdoor use where it freezes
ISO 10545-13Chemical resistanceKitchens, labs, pools, cleaning agents
ISO 10545-14Stain resistancePolished and glazed surfaces in homes, hotels and restaurants
ISO 10545-16Small colour differencesPlain colours; see shade variation

Slip resistance: four systems, no conversion

ISO 13006 and EN 14411 set no slip pass mark — the value and the method are declared. Markets use different tests, and there is no exact conversion between them, so ask for the one your project’s rules use.

SystemHow it is testedClasses or thresholdUsed in
R9–R13 (ramp, shod)A person in safety boots walks on an oiled ramp; the angle where walking becomes unsafe sets the class. Originally DIN 51130, now part of EN 16165:2021.R9 6–10°, R10 >10–19°, R11 >19–27°, R12 >27–35°, R13 >35°Germany, much of Europe, the GCC, India
A / B / C (ramp, barefoot)Bare feet on a ramp wet with soapy water (originally DIN 51097, now in EN 16165).A ≥12°, B ≥18°, C ≥24° (C is the most slip-resistant)Showers, changing rooms, pool surrounds
Pendulum test value (PTV)A pendulum swings a rubber slider over the wet surface (BS EN 16165, which replaced BS 7976). Slider 96 for shoes, Slider 55 for bare feet.UK guidance: 36+ low slip potential, 25–35 moderate, 0–24 highUnited Kingdom, Ireland
DCOFA tribometer drags a rubber test foot over the wet tile (ANSI A326.3).≥ 0.42 for level interior floors expected to be walked on when wet — not automatically suitable for every projectUnited States
AS 4586Wet pendulum classes P0–P5; ramp classes for some situations.P0 (lowest) to P5 (highest)Australia

Higher slip resistance usually means a rougher surface that is harder to clean, so choose the lowest class that is safe for the area — and remember that a polished and a matt tile of the same design are different products with different results. Our guide to slip ratings R9–R13 suggests classes by area.

What to ask for before you order

  • A test report per product, finish and thickness — with the laboratory, the date, the report number and the ISO 10545 part for each value.
  • For the EU: the manufacturer’s Declaration of Performance against EN 14411. For the UK: the UKCA declaration.
  • The slip test your market uses (R-class, PTV with slider, DCOF or AS 4586 class), for the exact finish.
  • The PEI class for glazed floor tiles, and frost resistance for anything outdoors.
  • Any market conformity scheme your country requires — for example the Saudi Quality Mark and SABER, Thailand’s TIS 2508 licence or a PVoC certificate in East Africa. Our market guides list them.
  • Who holds each certificate: plant certificates belong to the producing factory, which is named on our documents.

Reports are shared per product on request with your quotation, and an independent inspection before loading is always welcome — see our pre-shipment inspection guide. For colour lots and size sorting, read shade variation and calibre.

Sources (checked October 2026)