Import Guides

Slip ratings R9–R13 and where to use them

Slip ratings R9–R13 and where to use them

“Anti-skid” on a price list tells you very little. Slip resistance is measured, and the measurement you will see most often on European and Indian tile data sheets is the R-rating, from R9 to R13. Specifiers in the UK, Australia and the US use other methods as well. This guide explains what the R-ratings mean, how they relate to the other systems, and how to choose sensible ratings for different areas.

Key takeaways

  • R-ratings come from a ramp test with shod feet and oil (DIN 51130); R9 is the lowest class and R13 the highest.
  • Higher ratings are rougher, so they are harder to clean — choose the lowest rating that is safe for the area.
  • Barefoot wet areas use a separate A/B/C classification, not the R scale.
  • UK specifiers often want pendulum (PTV) values, Australia uses AS 4586 classes and the US uses DCOF.
  • Always ask for the test report for the specific product and finish.

How the R-rating is measured

The R-rating comes from the German ramp test of DIN 51130; since 2021 the ramp method is part of EN 16165, and the German edition keeps the R9–R13 classes in a national annex. A test person wearing standard safety boots walks forwards and backwards on a sample of the flooring laid on a ramp coated with motor oil. The ramp angle is gradually increased until the person can no longer walk safely. The average angle at which that happens determines the class:

Class Acceptance angle Typical description
R9 6°–10° Low slip resistance
R10 over 10°–19° Normal slip resistance
R11 over 19°–27° Increased slip resistance
R12 over 27°–35° High slip resistance
R13 over 35° Very high slip resistance

Because the test uses oil and footwear, it was designed for workplaces. It is widely quoted for all kinds of flooring, but it is only one view of slip resistance.

Where to use each rating

These are common starting points, not rules. Local regulations, the project’s risk assessment and the specifier’s judgement take precedence.

R9

Dry interior areas where contamination is unlikely: living rooms, bedrooms, offices, hotel rooms, dry retail floors. Most polished and glossy tiles fall here or below. Fine for appearance-led dry spaces; not for entrances that get wet.

R10

Interior areas that may occasionally get wet: domestic kitchens and bathrooms, shop and office entrances inside a matting zone, corridors, toilets in public buildings. Many matt GVT and full body tiles achieve R10.

R11

Areas that are often wet or exposed to the weather: external terraces, balconies, walkways, pool surrounds (shod), commercial kitchens with light contamination, ramps. Most 20 mm outdoor porcelain pavers are produced with R11 structured surfaces.

R12

Heavily contaminated work areas: commercial kitchens, food processing, car wash bays, some parking ramps. Texture is clearly noticeable and cleaning needs suitable equipment.

R13

Specialist industrial areas with heavy contamination by fats or oils, such as abattoirs or some food production. Rarely needed outside industry.

Barefoot areas: the A, B, C classes

For barefoot wet areas — showers, changing rooms, pool decks — a separate German test (DIN 51097, now also carried into EN 16165) uses bare feet and soapy water. Results are classed A, B or C, with C the most slip-resistant and typically specified for pool steps and walk-in pool edges. A tile can carry both an R-rating and an A/B/C class.

How other markets measure it

United Kingdom: pendulum test value (PTV)

UK guidance generally relies on the pendulum test (BS EN 16165, which replaced BS 7976 in 2022), which swings a rubber slider across the wet and dry surface and gives a pendulum test value. A wet PTV of 36 or more is widely treated as low slip potential. UK specifiers will often ask for wet PTV with the appropriate slider alongside or instead of an R-rating.

Australia: AS 4586

Australia classifies slip resistance under AS 4586, using pendulum classes (P0 to P5) and, for some situations, ramp classes. Building codes and handbooks reference the class appropriate to each location, so Australian buyers will usually ask for the AS 4586 classification of each product.

United States: DCOF

In the US, ANSI A137.1 and A326.3 use the dynamic coefficient of friction (DCOF), measured with a tribometer on a wet surface. A wet DCOF of at least 0.42 is commonly referenced for level interior floors expected to be walked on when wet; it is a minimum for the product, not a guarantee of safety in use.

There is no exact conversion between these systems. A tile rated R10 might perform well or poorly under a pendulum test depending on its texture and finish, so ask for the test your market actually uses.

Things that change slip resistance

  • Finish. The same design in polished, matt and structured finishes will test very differently.
  • Contamination. Water, soap, oil and dust change real-world slip far more than small differences in rating.
  • Maintenance. Wax or polish on a tile can reduce slip resistance; build-up of grease in a rough tile can too.
  • Wear. Heavy traffic can smooth a surface over time.
  • Slope. Ramps and sloped pool surrounds need more resistance than level floors.

What to ask your supplier

  1. Which test was used, by which laboratory, and when.
  2. Which finish was tested — make sure it is the same one you are ordering.
  3. Whether the report covers the production plant your tiles come from.
  4. For projects, whether a fresh test on a production sample is possible.

We supply slip test reports on request per product and plant, and can suggest suitable finishes for your project. Browse our 20 mm outdoor porcelain, see the Australia and UK market pages for local expectations, or request samples to feel the surface yourself.