Quality & Certifications

Quality

Quality & Certifications

We don't own the kilns yet. We set the standard, inspect every lot, and share product test reports from the producing plant or an accredited lab.

The Vitrano quality program

Five gates between the press and your port.

  1. 01

    Factory audit

    Partner plants are reviewed before an order is placed with them: raw material control, press tonnage, kiln curve, glaze lab, sorting line.

  2. 02

    Pre-production approval

    Shade and calibre reference tiles signed off by the buyer or our rep before the lot is fired.

  3. 03

    Lot inspection

    AQL 1.5 sampling on every lot: visual defects, tonality, flatness, edge straightness, back-stamp.

  4. 04

    Lab testing

    EN ISO 10545 tests by the producing plant or an accredited lab (e.g. NABL / SGS / Intertek). Product-specific reports on request.

  5. 05

    Loading supervision

    Container stuffing is supervised by us or an inspector you appoint; pallet-by-pallet photos, video and seal number are shared with you.

Illustrative render of a QC laboratory

Test matrix

ISO 13006 / EN 14411 Group BIa requirements.

These are the standard's requirements, not our test results. Tests are done by the producing plant or an accredited lab; product-specific reports are available on request. Slip resistance (DIN 51130, pendulum, DCOF) is not part of ISO 13006 and is declared per product only from a report.

StandardPropertyISO 13006 requirementApplies toProduct value
EN ISO 10545-2Dimensions & calibreLength/width ±0.6 % (max ±2.0 mm); thickness ±5 %All BIa tilesFrom test report, on request
EN ISO 10545-3Water absorptionAverage ≤ 0.5 %Vitrified / porcelain (BIa)From test report, on request
EN ISO 10545-4Breaking strength≥ 1,300 N (thickness ≥ 7.5 mm)Modulus of rupture ≥ 35 N/mm²From test report, on request
EN ISO 10545-6Deep abrasion (unglazed)≤ 175 mm³Full body / double chargeFrom test report, on request
EN ISO 10545-7Surface abrasion (glazed)Class to be reportedGVT / PGVTFrom test report, on request
EN ISO 10545-9Thermal shockTest method availableAll BIa tilesFrom test report, on request
EN ISO 10545-12Frost resistanceRequired where exposed to frostOutdoor useFrom test report, on request
EN ISO 10545-13Chemical resistanceHousehold chemicals & pool salts: min. GB / UBAll BIa tilesFrom test report, on request
EN ISO 10545-14Stain resistance (glazed)Min. class 3Glazed finishesFrom test report, on request

Certifications

Standards our products are tested and documented to.

  • EN 14411 Ceramic tiles standard Classification & DoP
  • ISO 13006 Tile specification Group B1a / B1b
  • ISO 10545 Test methods Lab reports per product
  • CE / UKCA Declaration of Performance From producing plant
  • SASO Saudi Quality Mark Plant-held · SABER per shipment
  • ISPM-15 Heat-treated pallets Every export load

Market-specific: SASO/SABER (KSA), ECAS (UAE), KEBS PVoC (Kenya), UKCA (UK), ANSI A137.1 & DCOF (USA), AS 4586 (Australia). Request copies via the form below.

Request for quotation

Ready to load your next container?

Send us sizes, finishes and quantities. We reply with FOB Mundra pricing, a packing list and a loading plan.

  • MOQ from one 20ft mixed container
  • Lead time 20–30 days ex-factory
  • 30% advance, 70% against B/L copy (LC accepted)

Send your requirement

Only if you would like a call or WhatsApp reply.

We reply as soon as possible.

We use these details only to answer this request and follow up on it. They are stored on our website and in our CRM (India). To access, correct or delete them, write to export@vitrano.in. EU/UK: processed to take the steps you ask for (GDPR Art. 6(1)(b)) or, for updates, with your consent.

Technical standard

ISO 13006 Group BIa — what porcelain tiles must meet

Requirement, ISO 10545 test method and where to find the product result. We quote product values only from a test report we hold for that product.

ISO 13006 / EN 14411 — Group BIa (E ≤ 0.5 %) requirements and ISO 10545 test methods
PropertyISO 13006 Group BIa requirementTest methodProduct result
Length, width & thicknessLength/width ±0.6 % (max ±2.0 mm); thickness ±5 % (max ±0.5 mm)ISO 10545-2See test report
Straightness, rectangularity, flatness±0.5 % (straightness max ±1.5 mm; rectangularity/flatness max ±2.0 mm)ISO 10545-2See test report
Surface quality≥ 95 % of tiles free from visible defectsISO 10545-2See test report
Water absorptionAverage ≤ 0.5 % (individual max 0.6 %)ISO 10545-3See test report
Breaking strength≥ 1,300 N (thickness ≥ 7.5 mm); ≥ 700 N (< 7.5 mm)ISO 10545-4See test report
Modulus of ruptureAverage ≥ 35 N/mm² (individual min 32 N/mm²)ISO 10545-4See test report
Surface abrasion, glazed (PEI class)Class and cycles to be reportedISO 10545-7See test report
Deep abrasion, unglazed≤ 175 mm³ISO 10545-6See test report
Linear thermal expansionTest method availableISO 10545-8See test report
Thermal shock resistanceTest method availableISO 10545-9See test report
Moisture expansionTest method availableISO 10545-10See test report
Crazing resistance, glazedRequired (no crazing)ISO 10545-11See test report
Frost resistanceRequired where tiles are exposed to frostISO 10545-12See test report
Chemical resistanceHousehold chemicals & pool salts: min. GB (glazed) / UB (unglazed); acids & alkalis: class declaredISO 10545-13See test report
Stain resistance, glazedMin. class 3ISO 10545-14See test report

Requirement values summarised from ISO 13006 Annex G — verify against the current ISO 13006 / EN 14411 edition. Slip resistance has no pass mark in ISO 13006 / EN 14411: the value and method (EN 16165 ramp or pendulum, ANSI A326.3 DCOF) are declared and tested separately.

Technical standards explained: ISO 13006, ISO 10545, EN 14411 and slip tests